GrippaPro 13 Litre Softening Cabinet Softner System
- It uses the unique SPECTRUM 5 Valve for compact design and complete control.
- Its ready to install with integral vessel, resin, brine tank and brine valve system.
- Tested and certified for reliability and peace of mind. NSF 44 tested & certified.
- It precisely measures the volume of soft water produced, optimising salt usage.
- Minimal regenerations - this means less wastewater to drain during regeneration process.
- Clear operational information on the LCD display.
- The visual alarm indicates when the salt refill is due.
- Immediate or delayed regeneration for flexibility and optimal salt usage.
- The integrated bypass allows usage of hard water when soft water is not required.
- The blending valve provides complete control over hardness.
- The quality components meet PED & CE directives.
- Easy programming so you can adapt settings to your needs.
Please note:- whilst softened water can be drunk, it is highly recommended that a separate mains supply with carbon filtration is installed/maintained for human consumption.
- Maximum Operating Temperature (ºC) 42
- Minimum Operating Temperature (ºC) 1
- Maximum Operating Pressure (bar) 8
- Minimum Operating Pressure (bar) 2
- Hydrostatic Test Pressure (bar) 20
- Resin volume: 13 (L)
- Optimal flow rate (m3/hr): 0.5
- Max flow rate (m3/hr): 4.5
- H (MM): 660
- W (MM): 333
- D (MM): 505
- In/Out ["]: 3/4 BSPM
Additional items needed to set up your water softener as per the instruction manual:-
- 1 x 25KG Granular Softener Salt [HYDROSOFT]
- 4 x 1/2" x 3/4 bsp FEMALE ADAPTOR (Genuine John Guest Part) [PI451616CS]
- 6 mtrs (or as required) 1/2" LLDPE TUBE - NATURAL - Per Metre PE-16-GI-0250F-N Genuine John Guest Part
- 1 x 25 Litres Tulsion Softner Resin Beads [T-42]
- 4 x 1/2" - 1/2" TUBE - HOSE STEM [PI251616s]
- 4 x 13mm x 20mm Single Mild Steel Jubilee Clip [00-MS]
How often does a Spectrum 13 Water Softener need to regenerate, and hence how often would it need to be refilled with salt?
As an example:
Capacity @ 450ppm = 1.4m3 (1400 litres)
If customer uses 700 litres per day then;
1400 litres / 700 litres = system regen every 2 days
System Salt Storage Capacity = 10 kg
System Salt Consumption per Regen = 1.5 kg
Regeneration before Salt used up = 10 kg / 1.5 kg = 6 regens
Salt Top Up therefore required every 12 days.